Owing to our sophisticated technologies, we manufacture a broad array of Digital Turbidity Meter VSI-13 & Digital Nephelo Meter VSI-13N. These meter models are completely digitalized and hence help in enhancing the measurement process. We also offer two models of Microprocessor Based Turbidity Meter VSI-701 & VSI-702. These instruments are widely used for testing the sewage and drinking water, these meters can be easily handled and demand less maintenance.
CLICK THE LINK GIVEN BELOW TO VIEW/DOWNLOAD ALL OUR LEAFLETS.
www.4shared.com/dir/5DsrzlE1/sharing.html
We are one of the leading manufacturers of Turbidity Meters. The Digital Turbidity Meter (VSI-13) is very accurate & stable instrument for measurement of turbidity upto 1000 NTU/JTU.
It has the following features:
Technical Specifications : VSI-13
Range |
0 to 1000 NTU/JTU in 2 Ranges |
Display |
3½ digit LED |
Accuracy |
+- 3% Full Scale +- 1digit |
Resolution |
1 NTU/JTU |
Detector |
Photo diode |
Light Source |
6.8 V, 250 mA Lamp |
Sample System |
30 mm. dia Clear Glass Test Tubes |
Calibration |
With Formazine Solution |
Power Supply |
230V +-10%, 50 Hz AC with built-in Voltage Stabilizer |
Standard Accessories |
One Set of 3 Glass Test Tubes of 30 mm. Dia & Instruction Manual. |
We are one of the leading manufacturers of Turbidity/Nephelo Meters. The Digital Nephelo Meter (VSI-13N) is very accurate & stable instrument for measurement of turbidity upto 200 NTU.
It has the following features:
Technical Specifications : VSI-13N
Range |
0 to 200 NTU |
Display |
3½ digit LED |
Accuracy |
+-2% Full Scale +- 1digit |
Resolution |
0.01 NTU |
Detector |
Photo diode |
Light Source |
6.8 V, 250 mA Lamp |
Sample System |
30 mm. dia Clear Glass Test Tube |
Calibration |
With Formazine Solution |
Power Supply |
230V +-10%, 50 Hz AC with built-in Voltage Stabilizer |
Standard Accessories |
One Set of 3 Glass Test Tubes of 30 mm. dia & Instruction Manual. |
Microprocessor Turbidity Meter - VSI-701 is the most accurate and reliable instrument for measurement of suspended solids/Turbidity levels in the samples. It has in-built memory to retain both range standard solution and last set value even after power loss.
It is extremely useful for measurement of suspended solids/turbidity levels in Sewage Water, Ground Water, Potable Water, Soil Analysis Laboratories, Fisheries, Water Quality Control in Boiler Feed Water, Water Works Department, Breweries, Water Purification Plants, Chemical & Pharmaceutical Industries, etc.
Features:
Technical Specifications:
Range |
Two Ranges 0 to 200 JTU/NTU and 200 to 1000 JTU/NTU |
Display |
16 Characters * 2 lines Alphanumeric LCD |
Accuracy |
+-3% of Full Scale Deflection in 0-1000 JTU/NTU |
Sample System |
30 mm. Clear Glass Cuvettes |
Light Source |
6.8 Volt, 0.3 Amp. Tungsten Lamp |
Detector |
Photodiode |
Memory |
In-built memory to retain both range standard solution and last set value even after power loss |
Calibration |
With Formazine Solution |
Power Supply |
230 Volt +- 10%, 50 Hz AC |
Microprocessor Based Turbidity Meter – (VSI-702) is designed to provide the precise Turbidity & Temperature measurements in the samples. The instrument uses the latest Microprocessor technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. The instrument has user friendly prompts which guide you throughout the measurement process. It has Auto Ranging facility in Turbidity Parameter.
The instrument has 6 soft touch membrane type keys with audible sound for ease of operation. It has the data storage facility for 1000 samples, which are retained in the memory even when the instrument is switched OFF. Provision has also been provided for attachment of centronix dot matrix printer so that any of the stored results can be printed.
It is extremely useful for measurement of suspended solids/turbidity levels in Sewage Water, Ground Water, Potable Water, Soil Analysis Laboratories, Fisheries, Water Quality Control in Boiler Feed Water, Water Works Department, Breweries, Water Purification Plants, Chemical & Pharmaceutical Industries, etc.
FEATURES of MICROPROCESSOR TURBIDITY METER VSI-702 :
Technical Specifications of Microprocessor Turbidity Meter (VSI-702)
Function Turbidity & Temperature Simultaneously |
Display 16 Characters x 2 Lines Alphanumeric LCD |
Power Supply 230 V ± 10%, 50 Hz AC |
TURBIDITY MEASUREMENT |
Range 0 – 1000 NTU in Two Ranges |
Resolution 0.1 NTU in lowest Range |
Accuracy ± 3% FS ± 1 Digit |
Range Selection Automatic |
Detector Photodiode/Photocell |
Sample System 30 mm. Clear Glass Test Tube |
Calibration Manual |
Light Source 6 V Tungsten Lamp |
Display Format Temperature & Turbidity Simultaneously |
TEMPERATURE MEASUREMENT |
Range -20˚C to +200˚C |
Resolution 0.1 ˚C |
Accuracy ± 0.1% of Range ±1 Digit |
Calibration Two Point Manual |
Sensor Pt-100 Probe |
Data Entry By Six Soft Touch Keys with Audible Sound |
Storage Memory 1000 Samples |
Real time display 24 Hour Mode with Date |
Interface RS-232,Centronics & Computer |
Print Format All Data & Date Wise (Programmable) |
Digital Output Serial RS-232 & Parallel Centronics |
STANDARD ACCESSORIES : Temperature Probe, Test Tubes, Data Cable & Instruction Manual. |
: PRINT FORMAT :
DATE |
TIME
|
TEMP(oC) |
PARAMETER
|
MODE
|
Sample No. (SP. No.) |
05/07/10 |
10:20 |
T= 020.0 |
|
MANUL |
001 |
05/07/10 |
10:21 |
T= 020.0 |
|
MANUL |
002 |
05/07/10 |
10:22 |
T= 020.0 |
|
MANUL |
003 |
Note: Appearance & Specifications are subject to change due to continuous development.
Submit a request to get commercial offer by visiting our Contact Us page.
VSI ELECTRONICS PVT. LTD.
info.vsielectronicsmohali@gmail.com
F-330, PHASE VIII-B, SECTOR 74, INDUSTRIAL AREA, S.A.S. NAGAR, MOHALI - 160071, CHANDIGARH (INDIA).
+91-172-4627238,
+91-9855076463, 9814016463,
+91-9041931993